Test Code ARMASO Acetylcholine Receptor Modulating Antibody (0099521)
Additional Codes
ARUP Test Code: 0099521
Useful For
Assessment of clinical activity of and initialdiagnostic testing for myasthenia gravis.
Synonyms/Keywords
Acetylcholine Receptor Modulating Antibodies (0099521)
AChR Antibody
ACHR modulating antibody
Muscle nicotinic Acetylcholine Receptor (AChR) Modulating Antibody
Myasthenia Gravis Antibodies
Specimen Requirements
| Fasting Required | Specimen Type | Preferred Container/Tube | Acceptable Container/Tube | Specimen Volume | Specimen Minimum Volume (allows for 1 repeat) |
Pediatric Minimum Volume (no repeat) |
|---|---|---|---|---|---|---|
| No | Serum | Serum Separator Tube (SST) | 0.5 mL | 0.3 mL |
Specimen Stability Information
| Specimen Type | Temperature | Time |
|---|---|---|
| Serum | Ambient | 48 hours |
| Refrigerated | 14 days | |
| Frozen | 1 year |
Rejection Criteria
Gross hemolysis
Gross lipemia
Contaminated specimen
Interpretations
Approximately 85-90 percent of patients with myasthenia gravis (MG) express antibodies to the acetylcholine receptor (AChR), which can be divided into binding, blocking, and modulating antibodies. Binding antibody can activate complement and lead to loss of AChR. Blocking antibody may impair binding of acetylcholine to the receptor, leading to poor muscle contraction. Modulating antibody causes receptor endocytosis resulting in loss of AChR expression, which correlates most closely with clinical severity of disease. Approximately 10-15 percent of individuals with confirmed myasthenia gravis have no measurable binding, blocking, or modulating antibodies.
Reference Interval: Negative 0-45% modulating; Positive 46% or greater modulating.
This test was developed and its performance characteristics determined by ARUP Laboratories. It has not been cleared or approved by the US Food and Drug Administration. This test was performed in a CLIA certified laboratory and is intended for clinical purposes.
Reference Range Information
| Performing Location | Reference Range |
|---|---|
| ARUP Laboratories |
Negative 0-45% modulating |
Performing Laboratory Name
ARUP Laboratories
Referral Laboratory Information
| Address | Telephone | Website Link | Marshfield Lab Account # |
|---|---|---|---|
|
500 Chipeta Way Salt Lake City, UT 84108-1221 |
800-522-2787 | 12057 |
Performing Information
| Performing Location | Day(s) Test Performed | Analytical Time | Methodology/Instrumentation |
|---|---|---|---|
| ARUP Laboratories | Sunday through Friday | 2-7 days | Semi-Quantitative Flow Cytometry |
CPT Codes
| CPT | Modifier (if needed) |
Quantity | Description | Comments |
|---|---|---|---|---|
| 86043 | 1 |
Outreach CPT Codes
| CPT | Modifier (if needed) |
Quantity | Description | Comments |
|---|---|---|---|---|
| 86043 | 1 |
Ordering Applications
| Ordering Application | Description |
|---|---|
| COM | Acetylcholine Receptor Mod Abs (0099521) |
| Cerner | Acetylcholine Receptor Modulating Antibodies (0099521) |