Sign in →

Test Code BLOD1547 Soybean Allergen Reflex to Components

Important Note

This test is replacement for previous Sanford test BLOD0756 (Soybean Allergen) which was made obsolete on 5/19/2026. 

This test can be ordered as MISC currently (until IT build of this test is complete).  Any orders for BLOD0756 will be cancelled and replaced with BLOD1547.

AKA

Food

Soybean

Specimen Type/Requirements

Gold top (Serum w/gel) tube - Serum

Red top (Serum w/out gel) tube - Serum

 

Test is not affected by hemolysis or lipemia.

Specimen Volume

 Preferred Volume     2.0 mL   
 Minimum Volume     1.0 mL   

Additional Information

If Soybean Allergen is positive the test will reflex to 3 components (RGLY M4 PR-10, NGLY M5 Beta Conglycinin, NGLY M6 Glycinin) at an additional charge.

Stability/Transport

 Room Temperature     Not Acceptable     
 Refrigerated     7 days     Preferred for transport   
 Frozen     30 days     

Performed Test Frequency

Monday through Friday

Report Available

1 – 3 days

Methodology

Fluoroallergrosorbent

Performing Lab

Sanford Laboratories Sioux Falls

CPT

86003

Marshfield Labs Test Catalog Note:

If positive, will reflex Soy Allergen Component Panel (CPTs:  86008 x 3)

Interface Build Information

Result Code  Result Code Description 
3726 Food: Soybean Quant
3723 Food: Soybean Class