Test Code CA19-9O Carbohydrate Antigen 19-9, Body Fluid

Useful For

An adjunct marker in the assessment of pancreatic cysts when used in conjunction with CEA, amylase, imaging studies and cytology.

 

An adjuvant to cytology and imaging studies to differentiate between nonmalignant and malignant causes of pleural effusions & peritoneal fluid.

Specimen Requirements

Specimen Type Preferred Container/Tube Acceptable Container/Tube Specimen Volume Specimen Minimum Volume
(allows for 1 repeat)
Pediatric Minimum Volume
(no repeat)
Pancreatic Cyst Fluid / Body Fluid Body Fluid container Plastic vial 300 uL 100 uL N/A

Collection/Processing Instructions

Do not collect the specimen with preservatives or anticoagulants.

 

Specimens should be centrifuged to remove cells or clots if present.

Specimen Stability Information

Specimen Type Temperature Time
Pancreatic Cyst Fluid / Body Fluid Ambient N/A
Refrigerated 7 days
Frozen at -20 deg Celsius 30 days
Frozen at -70 deg Celsius > 30 days

Rejection Criteria

Blood or Urine

Interferences

The possibility exists for interference by heterophile antibodies & HAMA in the patient sample regularly exposed to animals or has received immunotherapy or diagnostic procedures utilizing immunoglobulins or immunoglobulin fragments.

Interpretations

Diagnosis of a pancreatic cyst is often difficult and requires correlation of imaging studies, cytology studies and tumor marker results on cyst aspirates. High concentrations of Carbohydrate antigen 19-9 (CA 19-9) in pancreatic cyst fluid may be helpful in distinguishing between benign and malignant cysts.

Based on evidence available and recommendations by the American College of Gastroenterology (ACG) practice guidelines for the Diagnosis and Management of Neoplastic Pancreatic Cysts (Am. J. Gastroenterol. 2007; 102: 2339-2349), a pancreatic cyst fluid CA 19-9 < 37 U/ml has high specificity to excludes mucinous cyst. A low (<5 U/ml) or negative result may be uninformative or misleading as some individuals do not produce CA 19-9 antigens. Serum CA 19-9 should be measured to verify if a patient is a CA 19-9 secretor or not.

This test should be performed in conjunction with CEA & Amylase and should not be ordered for pancreatic fluid of non-cyst origin.

Reference Range Information

Performing Location Reference Range
Marshfield Reference cut-off limits for CEA for pancreatic cyst fluid and other body fluids have not been established and verified.

The test results should not be the sole basis of diagnosis and always be correlated with imaging and cytology.

Marshfield Labs Performing Department

Marshfield Labs Chemistry

Performing Information

Performing Location Day(s) Test Performed Analytical Time Methodology/Instrumentation
Marshfield Monday through Friday Less than 2 hours Two-step Sandwich Immunoassay using Direct Chemiluminometric Technology/Siemens Centaur

CPT Codes

CPT Modifier
(if needed)
Quantity Description Comments
86301        

Outreach CPT Codes

CPT Modifier
(if needed)
Quantity Description Comments
86301