Sign in →

Test Code FIB Fibrinogen, Plasma Quantitative

Synonyms/Keywords

Factor I, Clottable Fibrinogen

Specimen Requirements

Fasting Required Specimen Type Preferred Container/Tube Acceptable Container/Tube Specimen Volume Specimen Minimum Volume
(allows for 1 repeat)
Pediatric Minimum Volume
(no repeat)
No Whole Blood, Plasma 3.2% Citrated Blue Top Tube (BTT)   0.75 mL  Plasma 0.5 mL  Plasma  

Collection/Processing Instructions

  • Citrated Blue Top Tube (BTT) must be drawn to the fill line.
  • Completely invert tube three or four times to mix. Do Not Shake.
  • Centrifuge tube at 3000 rpm for 10 minutes or Stat Spin for 3 minutes at 8500 rpm with the brake OFF as soon as possible after collection.
  • Perform testing within 24 hours of specimen collection.

Specimen Stability Information

Specimen Type Temperature Time
Whole Blood or Plasma Ambient or Refrigerated 24 Hours
Plasma Frozen (-18C) 2 Weeks
Frozen (-70C) 6 Months
Frozen thawed 2 Hours

Rejection Criteria

Reject at gross hemolysis
Specimens filled below the fill line
Clotted
Frozen whole blood
Known IV fluid or Hickman line fluid contamination
Specimens with abnormal results that have  a Hct >55% that have not had the citrate anticoagulant adjusted

Test Information

Moderate hemolysis does not interfere with sample analysis, however it may be an indicator of clotting factor activation prior to testing.  Clinical correlation with results recommended.

Reference Range Information

Performing Location Reference Range
Marshfield 159 - 462 mg/dL
See Critical Value List for list of current critical values

Marshfield Labs Performing Department

Marshfield Labs Hematology

Performing Information

Performing Location Day(s) Test Performed Analytical Time Methodology/Instrumentation
Beaver Dam Monday through Sunday Less than 2 hours Optical Clot Detection/Sysmex CS-2500
Weston Monday through Sunday Less than 2 hours Optical Clot Detection/Sysmex CS-2500
Eau Claire Monday through Sunday Less than 2 hours Optical Clot Detection/Sysmex CS-2500
Park Falls Monday through Sunday Less than 2 hours Optical Clot Detection/Sysmex CS-2500
Lakeview Medical Center Monday through Sunday Less than 2 hours Optical Clot Detection/Sysmex CS-2500
Marshfield Monday through Sunday Less than 2 hours Optical Clot Detection/Sysmex CS-2500
Minocqua Monday through Sunday Less than 2 hours Optical Clot Detection/Sysmex CS-2500

CPT Codes

CPT Modifier
(if needed)
Quantity Description Comments
85384        

Outreach CPT Codes

CPT Modifier
(if needed)
Quantity Description Comments
85384        

Ordering Applications

Ordering Application Description
Cerner Fibrinogen, Plasma Quantitative