Sign in →

Test Code HEPUF-CIR CRRT circuit HEPUF

Important Note

For internal ordering only. Only available to order at MMC-Marshfield. Not available to outreach clients.

Synonyms/Keywords

circuit, ECMO, HEPUF, anti-Xa

Specimen Requirements

Fasting Required Specimen Type Preferred Container/Tube Acceptable Container/Tube Specimen Volume Specimen Minimum Volume
(allows for 1 repeat)
Pediatric Minimum Volume
(no repeat)
No Plasma 3.2% Citrated Blue Top Tube (BTT)
 
1 mL 0.6 mL  

Collection/Processing Instructions

MMC-Marshfield ONLY

 

ECMO patients: Citrated Blue Top Tube (BTT) must be drawn to the fill line. Completely invert tube 3 to 4 times to mix. Do Not Shake! 

Specimen Stability Information

Specimen Type Temperature Time
Plasma Ambient 4 hours

Rejection Criteria

Gross Hemolysis

Specimens filled below the fill line

Clotted

Test Components

HEPUF

Reference Range Information

No reference range established for this analyte/sample type

Marshfield Labs Performing Department

Marshfield Labs Hematology

Performing Information

Performing Location Day(s) Test Performed Analytical Time Methodology/Instrumentation
Marshfield Monday through Sunday Less than 2 hours Anti-Factor Xa Chromogenic/Sysmex CS-2500

CPT Codes

CPT Modifier
(if needed)
Quantity Description Comments
 
85520        

Ordering Applications

Ordering Application Description
Cerner CRRT circuit HEPUF