Sign in →

Test Code HLATX HLA-AB Low Resolution (2303)

Additional Codes

Versiti Test Code: 2303

Synonyms/Keywords

HLA Typing for Transplant

Specimen Requirements

Submit 1 of the following sample types.
Specimen Type Preferred Container/Tube Acceptable Container/Tube Specimen Volume Specimen Minimum Volume
(allows for 1 repeat)
Pediatric Minimum Volume
(no repeat)
Buccal swabs Buccal swabs   4 swabs 3 swabs  

Whole blood

or

Cord blood

EDTA Lavender Top Tube (LTT)   14 mL 5 mL  

Collection/Processing Instructions

Indicate on specimen tube and requisition whether the sample is whole blood or cord blood. Contact Versiti Lab if sending cord blood or DNA. Test requisition must state if sample is from a "recipient", "donor" or "non-transplant" draw.  Send only 14 mL EDTA whole blood OR 4 buccal swabs if more than one HLA typing test is ordered.  Submit samples at room temperature. 

Specimen Stability Information

Specimen Type Temperature Time
Buccal swabs OR Whole blood Ambient 7 days
 

Rejection Criteria

Refrigerated samples
Frozen samples

Reference Range Information

No reference ranges are available.

Performing Laboratory Name

Versiti Wisconsin

Referral Laboratory Information

Address Telephone Website Link Marshfield Lab Account #
638 N. 18th Street Milwaukee, WI 53233 800-245-3117 https://www.versiti.org 588

Performing Information

Performing Location Day(s) Test Performed Analytical Time Methodology/Instrumentation
Versiti Monday, Wednesday, Friday 5-7 days PCR-rSSO, -SSP (melt curve analysis), and/or Direct DNA Sequencing

CPT Codes

CPT Modifier
(if needed)
Quantity Description Comments
81373   2 One locus each (HLA-A and B)  

Outreach CPT Codes

CPT Modifier
(if needed)
Quantity Description Comments
81373   2 One locus each (HLA-A and B)  

Ordering Applications

Ordering Application Description
Centricity HLA Typing-Recipient
Cerner HLA Typing for Transplant-Blood Ctr (2303)