Test Code HORIZSO Horizon 14 Carrier Screen
Useful For
Horizon genetic carrier screening helps couples determine the risk of passing on serious genetic conditions to their child. The 14-condition panel screens for 12 autosomal recessive conditions and 2 X-linked conditions.
Synonyms/Keywords
Cystic Fibrosis
Spinal Muscular Atrophy
Specimen Requirements
| Fasting Required | Specimen Type | Preferred Container/Tube | Acceptable Container/Tube | Specimen Volume | Specimen Minimum Volume (allows for 1 repeat) |
|---|---|---|---|---|---|
| No | Whole Blood | EDTA Lavender Top Tube (LTT)- provided in Horizon collection kit | Call Lab Customer Service Technical Staff at 715-221-6700 (1-6700) | 6 mL | 6 mL |
Collection/Processing Instructions
Collect one 6 mLLavender-top EDTA tube from kit. Do not expose blood to temperatures outside ofthe range of 43-98° F. Do not seal tubes with paraffin film. DO NOT REFRIGERATE OR FREEZE sample at anytime. Store and transport specimen tubesat ambient temperature (43-98 F or 6-37 C). Do not collect in expired tubes.Do not place specimen label over lot number or expiration date of tube.
Specimen Stability Information
Store and transport specimen tubesat ambient temperature (43-98 F or 6-37 C).
Rejection Criteria
Refrigerated specimens
Frozen specimens
Interpretations
An interpretive report will be provided.
Reference Range Information
An interpretive report will be provided.
Performing Laboratory Name
Natera, Inc.
Referral Laboratory Information
| Address | Telephone | Website Link | Marshfield Lab Account # |
|---|---|---|---|
|
201 Industrial Rd. Ste 410 San Carlos, Ca 94001 |
650-249-9090 | www.natera.com |
Note: Natera also performs testing in Austin, Texas. Samples will be sent to either California or Texas, depending on what address is listed on the prepaid address label provided by Natera.
Performing Information
| Performing Location | Day(s) Test Performed | Analytical Time | Methodology/Instrumentation |
|---|---|---|---|
| Natera Labs | Monday through Sunday |
2 weeks |
Next-Generation Sequencing (NGS) |
CPT Codes
| CPT | Modifier (if needed) |
Quantity | Description | Comments |
|---|---|---|---|---|
| 81200 | 1 | |||
| 81329 | 1 | |||
| 81220 | 1 | |||
| 81243 | 1 | |||
| 81251 | 1 | |||
| 81255 | 1 | |||
| 81257 | 1 | |||
| 81260 | 1 | |||
| 81401 | 1 | |||
| 81161 | 1 | |||
| 81400 | 1 | |||
| 81361 | 1 | |||
| 81405 | 1 | |||
| 81408 | 1 |
Ordering Applications
| Ordering Application | Description |
|---|---|
| Cerner | Horizon Custom, Carrier Screening (CF/SMA) |