Test Code MUXF3SO MUXF3 (Cross-reactive Carbohydrate Determinant), IgE, Serum
Additional Codes
Mayo Test Code: MUXF3
Ordering Guidance
For a listing of allergens available for testing, see Allergens - Immunoglobulin E (IgE) Antibodies
Specimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 0.5 mL for every 5 allergens requested
Collection Instructions: Centrifuge and aliquot serum into a plastic vial.
Forms
If not ordering electronically, complete, print, and send an Allergen Test Request (T236) with the specimen.
Useful For
Evaluation for the presence of antibodies to cross-reactive carbohydrate determinates
Investigation of clinically unexpected positive IgE antibody testing in a wide variety of plant and invertebrate allergens
This test is not useful for patients previously treated with immunotherapy to determine if residual clinical sensitivity exists or in patients in whom the medical management does not depend upon identification of allergen specificity.
Special Instructions
Method Name
Fluorescence Enzyme Immunoassay (FEIA)
Reporting Name
MUXF3 (CCD), IgE, SSpecimen Type
SerumSpecimen Minimum Volume
For 1 allergen: 0.3 mL
For more than 1 allergen: (0.05 mL x number of allergens) + 0.25 mL deadspace
Specimen Stability Information
| Specimen Type | Temperature | Time |
|---|---|---|
| Serum | Refrigerated (preferred) | 14 days |
| Frozen | 90 days | |
| Ambient | 7 days |
Reject Due To
| Gross hemolysis | OK |
| Gross lipemia | OK |
| Gross icterus | OK |
Reference Values
|
Class |
IgE kU/L |
Interpretation |
|
0 |
<0.10 |
Negative |
|
0/1 |
0.10-0.34 |
Borderline/equivocal |
|
1 |
0.35-0.69 |
Equivocal |
|
2 |
0.70-3.49 |
Positive |
|
3 |
3.50-17.4 |
Positive |
|
4 |
17.5-49.9 |
Strongly positive |
|
5 |
50.0-99.9 |
Strongly positive |
|
6 |
≥100 |
Strongly positive |
Reference values apply to all ages.
Concentrations of 0.70 kU/L or more (class 2 and above) will flag as abnormally high.
Cautions
Some individuals with clinically insignificant sensitivity to allergens may have measurable levels of IgE antibodies in serum, and test results must be interpreted in the clinical context.
False-positive results for IgE antibodies may occur in patients with markedly elevated serum IgE (>2500 kU/L) due to nonspecific binding to allergen solid phases.
Specimen Retention Time
14 daysPerforming Laboratory
Mayo Clinic Laboratories in Rochester
Test Classification
This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.CPT Code Information
86008
LOINC Code Information
| Test ID | Test Order Name | Order LOINC Value |
|---|---|---|
| MUXF3 | MUXF3 (CCD), IgE, S | 58984-6 |
| Result ID | Test Result Name | Result LOINC Value |
|---|---|---|
| MUXF3 | MUXF3 (CCD), IgE, S | 58984-6 |
Day(s) Performed
Monday through Friday