Test Code PAI1 Plasminogen Activator Inhibitor Antigen, Plasma

Important Note

Test is to be ordered as "MISC"

Additional Codes

Mayo Test Code: PAI1


Specimen Required


Specimen Type: Platelet-poor plasma

Collection Container/Tube: Light-blue top (3.2% sodium citrate)

Submission Container/Tube: Plastic vial (polypropylene preferred)

Specimen Volume: 1 mL Platelet-poor plasma

Collection Instructions:

1. For complete instructions, see Coagulation Guidelines for Specimen Handling and Processing.

2. Centrifuge, transfer all plasma into a plastic vial, and centrifuge plasma again.

3. Aliquot plasma into a plastic vial leaving 0.25 mL in the bottom of centrifuged vial.

4. Freeze plasma immediately (no longer than 4 hours after collection) at -20° C or, ideally, at-40° C or below.

Specimen Stability Information: Frozen 2 years

Additional Information:

1. A double-centrifuged specimen is critical for accurate results as platelet contamination may cause spurious results.

2. Each coagulation assay requested should have its own vial.


Useful For

Identification of heredity elevation or deficiency of plasminogen activator inhibitor type 1

 

Determination of risk for veno-occlusive disease associated with bone marrow transplantation

 

Differential diagnosis of impaired fibrinolysis

 

Prognostic marker of occurrence or recurrence of thrombosis

Method Name

Enzyme-Linked Immunosorbent Assay (ELISA)

Reporting Name

PAI-1 Ag, P

Specimen Type

Plasma Na Cit

Specimen Minimum Volume

Platelet-poor plasma: 0.5 mL

Specimen Stability Information

Specimen Type Temperature Time
Plasma Na Cit Frozen

Reject Due To

Gross hemolysis Reject
Gross lipemia Reject
Gross icterus Reject

Reference Values

3.0-72.0 ng/mL

Cautions

The plasminogen activator inhibitor type 1 (PAI-1) level shows a diurnal variation with the highest levels occurring in the morning.

 

The PAI-1 level increases during pregnancy and decreases rapidly after delivery.

 

The extremely rare presence of antimouse antibodies in certain patients may lead to anomalous results.

 

Inappropriate specimen collection and processing may lead to platelet activation and release of platelet PAI-1. Consequently, care must be taken to remove all platelets and minimize platelet activation during specimen collection and processing.

Day(s) Performed

Wednesday

Report Available

7 to 12 days

Specimen Retention Time

7 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information

85415

LOINC Code Information

Test ID Test Order Name Order LOINC Value
PAI1 PAI-1 Ag, P 22758-7

 

Result ID Test Result Name Result LOINC Value
86083 PAI-1 Ag, P 22758-7