Sign in →

Test Code Path GYN, Liq Prep Rflx ASCUS+&Geno Cytology, Pap, Liquid Prep w/HPV if ASCUS Plus + HPV Genotyping Reflex

Important Note

Order as "Pathology Gyn Request"

Useful For

The cervicovaginal smear is a test for the detectionof premalignant, cellular changes, which are precursors to carcinoma of thecervix. The conventional pap smear, when used as part of a regular screening program has been credited with reducing the incidence of cervical cancer worldwide.  


The Thin-Prep pap test has been approved by the U.S. Food and DrugAdministration as a replacement for the conventional pap smear and is endorsedby the College of American Pathologists as a method to improve the accuracy ofpap examinations. The Thin Prep pap test improves detection oflow-grade and more severe lesions.  By improving detection, disease can beidentified at an earlier stage when it is more easily and cost-effectively treated. 

Synonyms/Keywords

Pathology GYN Request – Liquid Prep Reflex ASCUS+ +Geno

Specimen Requirements

Specimen Type Preferred Container/Tube Acceptable Container/Tube Specimen Volume Specimen Minimum Volume
(allows for 1 repeat)
  ThinPrep Vial   20 mL  

 

Collection/Processing Instructions

Obtain an adequate sampling from the ectocervix using a plastic spatula. Immediately rinse the spatula into the ThinPrep PreservCyt Solution vial by swirling the spatula vigorously in the vial 10 times. Discard the spatula. Obtain an adequate sampling from the endocervix using an endocervical brush device. Insert the brush into the cervix until only the bottom-most fibers are exposed. Slowly rotate 1/4 to 1/2 turn in one direction. DO NOT OVER-ROTATE. Immediately rinse the brush in the PreservCyt Solution by rotating the device in the solution 10 times while pushing against the PreservCyt vial wall. Swirl the brush vigorously to further release material. Discard the brush. Tighten the cap so that the torque line on the cap passes the torque line on the vial.

 

Record the patient name and medical record number on the vial.

 

HPV Orders: If ThinPrep Pap and HPV if ASCUS or Higher is requested in the original order, the PreservCyt ThinPrep vial will be processed as a pap first and then the HPV test will be tested by the Molecular Pathology Department if the Pap Interpretation is : Atypical Squamous Cells of Undetermined Significance (ASC-US), Atypical Squamous Cells Cannot Exclude High Grade Squamous Intraepithelial Lesion (ASC-H), Low Grade Squamous Intraepithelial Lesion (LSIL), High Grade Squamous Intraepithelial Lesion (HSIL), Favor Neoplastic or Malignant Cells Present.  

 

NOTE: Self-collected pap tests are not FDA approved and will be rejected by the laboratory. 

Specimen Stability Information

Specimen Type Temperature Time
ThinPrep Ambient 4 weeks

Rejection Criteria

See HUMAN PAPILLOMAVIRUS (HPV)

Frozen specimen

Self-collected specimen

Test Information

For additional HPV information, see the Human Papillomavirus (HPV).

For additional HPV Genotyping information, see HPV-Human Papillomavirus Genotyping 16,18/45(NAM).
 

Include specimen source, pertinent patient history and clinical information along with the appropriate ICD-10 code on the electronic order or test requisition form. 

For Collection Techniques/Instructions see:

For list of a compatible lubricants and lubricant usage see:

For Appropriate ThinPrep Vial Labeling see:

 

Interferences

Lubricants may increase the risk of contaminating andobscuring the cellular sample. When collecting a specimen, warm water issuggested to lubricate and warm the speculum. If a lubricant must be utilized,a sparing application to the outer portion of the speculum, with avoidance ofthe tip, is recommended. The following lubricant brands are acceptable to usewith the PreServCyt Solution: Surgilube, CerviLube or Pap Test Lubricating Jelly.

Reference Range Information

Performing Location Reference Range
Marshfield-Cytopathology Interpretative Report (Bethesda System)

Marshfield Labs Performing Department

Marshfield Labs Cytopathology

Performing Information

Performing Location Day(s) Test Performed Analytical Time Methodology/Instrumentation
Marshfield-Cytopathology Monday-Friday 3 days ThinPrep/ Light Microscopy 

CPT Codes

CPT Modifier
(if needed)
Quantity Description Comments
88142     Screening Purposes - ThinPrep Pap  
88141     Screening Purposes - Interp. By Physician  
88142     Diagnostic Purposes - ThinPrep Pap  
88141     Diagnostic Purposes - Interp. By Physician  
87624     HPV - Hybrid Capture Method, if needed  
87625     HPV Genotyping (16, 18/45)(NAM)  

Outreach CPT Codes

CPT Modifier
(if needed)
Quantity Description Comments
88142     Screening Purposes - ThinPrep Pap  
88141     Screening Purposes - Interp. By Physician  
88142     Diagnostic Purposes - ThinPrep Pap  
88141     Diagnostic Purposes - Interp. By Physician  
87624     HPV - Hybrid Capture Method, if needed  
87625     HPV Genotyping (16, 18/45) (NAM)